The high-density fiber distribution cabinet is core infrastructure adapted to the harsh operating conditions of nuclear power plants and designed for highly reliable optical signal aggregation. Featuring high-density integration, strong environmental endurance and high safety redundancy, it is the key physical carrier for the stable operation of nuclear instrumentation & control (I&C) systems and data communication networks.
Odoslať správu Získajte cenu
| Kabinet Materiál | Oceľový plech valcovaný za studena | Vonkajšie rozmery (mm) | 2500 800 × × 600 | ||||||
| Kapacita zásobníka na vlákna | 1 440 – 2 880 jadier | Hmotnosť (kg) | |||||||
| Štandardné príslušenstvo | |||||||||
| Nie. | Meno | Jednotka | Množstvo | Nie. | Meno | Jednotka | Množstvo | ||
| 1 | Telo skrinky | Sada | 1 | 6 | Zostava na upevnenie kábla | Sada | 2 | ||
| 2 | Káblové zväzky (nylonové) | Pc | 60 | 7 | 1U racková spájacia a distribučná jednotka | Pc | 30 | ||
| 3 | Rozpínacie kotviace skrutky | Pc | 4 | 8 | |||||
| 4 | Ochranná manžeta spoja | Pc | 2880 | 9 | |||||
| 5 | 1U organizér káblov | Pc | 15 | 10 | |||||
| Voliteľné príslušenstvo | |||||||||
| Nie. | Meno | Jednotka | Množstvo | Nie. | Meno | Jednotka | Množstvo | ||
| 1 | 12-žilový SC pigtail v balíku | Pc | 120 | 4 | Adapter SC | Pc | 1440 | ||
| 2 | 12-jadrový FC pigtail v balení | Pc | 120 | 5 | FC Adapter | Pc | 1440 | ||
| 3 | 12-žilový LC pigtail v balíku | Pc | 240 | 6 | LC duplexný adaptér | Pc | 1440 | ||
Ukazovatele prevádzkového prostredia:
Prevádzková teplota: -40 ℃ ~ + 85 ℃
Skladovacia teplota: -40 ℃ ~ +85 ℃
Prevádzková relatívna vlhkosť: ≤85 % (pri +30 ℃)
Relatívna vlhkosť pri skladovaní: ≤90 % – 96 % (pri 40 ℃ ± 2 ℃)
Atmosférický tlak: 70 – 106 kPa
Typické scenáre použitia:
Nuclear island I&C equipment room: centrally deployed in core controlled areas such as the HF building and the 220kV switchyard, it carries massive optical signal aggregation of the reactor I&C system, providing low-loss splicing, dispatching and full-link protection between trunk optical cables and I&C equipment, and completely avoiding the impact of strong electromagnetic interference on critical control signals.
Nuclear power data center equipment room: the high-density LC interface model meets 10G and 400G high-speed transmission requirements, supporting high-bandwidth data transmission for the nuclear power production management system and safety monitoring platform, with over 30% port redundancy reserved to meet expansion needs across the plant’s 60-year full life cycle.
Weak-current rooms of nuclear auxiliary buildings: it centrally manages the fiber links of subsystems such as video surveillance, security access control and environmental monitoring within the plant area, avoiding crossover confusion among links and greatly reducing troubleshooting time.
Poznámka: Špecifikácie sa môžu zmeniť bez predchádzajúceho upozornenia z dôvodu zlepšovania produktu.
Je vhodný pre rôzne scenáre spotreby energie, ako sú obytné budovy a komerčné kancelárske budovy.
Zaviazali sme sa poskytovať rýchlu a profesionálnu podporu, aby sme zabezpečili, že vaše energetické potreby budú vždy splnené s najvyššou úrovňou služieb.
Sme tu, aby sme odpovedali na vaše otázky a poskytli energetické riešenia, ktoré najlepšie vyhovujú vašim potrebám.